Research Repository

The determination of glucoraphanin in broccoli seeds and florets by solid phase extraction and micellar electrokinetic capillary chromatography

Trenerry, V. Craige and Caridi, Domenico and Elkins, Aaron and Donkor, Osaana N and Jones, Rod (2006) The determination of glucoraphanin in broccoli seeds and florets by solid phase extraction and micellar electrokinetic capillary chromatography. Food Chemistry, 98 (1). pp. 179-187. ISSN 0308-8146

Full text for this resource is not available from the Research Repository.

Abstract

A robust method for the determination of glucoraphanin in broccoli (brassica oleracea ssp. italica ‘Marathon’) seeds and florets has been developed using solid phase extraction (SPE) and micellar electrokinetic capillary chromatography (MECC) as the determinative step. Glucosinolates were extracted from the broccoli seeds and florets with hot water. Unwanted impurities were removed by passing the extracts through C18 and protonated amino propyl SPE cartridges connected in series. The glucosinolate fraction was removed from the protonated amino propyl cartridge with 2% v/v ammonia solution in methanol. The solvent was removed with a stream of nitrogen, the residue dissolved in water and the level of glucoraphanin determined by MECC using a 77 cm × 75-μm id bare fused silica capillary column (effective length 69.4 cm) and a buffer consisting of 18 mM sodium tetraborate, 30 mM sodium dihydrogen orthophosphate and 30 mM cetyltrimethylammonium bromide, pH 7. MECC parameters and capillary conditioning procedures were optimised with respect to reducing the analysis time without compromising peak integrity. The level of glucoraphanin in broccoli seeds and florets compared favorably with the levels determined by a validated high performance liquid chromatography (HPLC) literature procedure; broccoli seeds MECC 2.1 gm/100 g, HPLC 2.0 gm/100 g; broccoli florets, MECC 71 mg/100 g, HPLC 70 mg/100 g. The MECC instrument reproducibility data (n = 7) for glucoraphanin in broccoli seed and floret extracts for migration time (CV; seeds 1.2%, florets 2%) and area calculation (CV; seeds 3.7%, florets 7%) relative to the internal standard were suitable.

Item Type: Article
Uncontrolled Keywords: Glucoraphanin, broccoli seeds, broccoli florets, solid phase extraction, micellar electrokinetic capillary chromatography, high performance liquid chromatography
Subjects: RFCD Classification > 290000 Engineering and Technology
Faculty/School/Research Centre/Department > School of Engineering and Science
Depositing User: Ms Phung T Tran
Date Deposited: 24 Feb 2009 18:11
Last Modified: 16 Jan 2015 02:48
URI: http://vuir.vu.edu.au/id/eprint/1799
DOI: 10.1016/j.foodchem.2005.07.002
ePrint Statistics: View download statistics for this item
Citations in Scopus: 9 - View on Scopus

Repository staff only

View Item View Item