Stability and reproducibility of brachial artery flow-mediated dilation

Full text for this resource is not available from the Research Repository.

Welsch, Michael A, Allen, Jason and Geaghan, James P (2002) Stability and reproducibility of brachial artery flow-mediated dilation. Medicine and Science in Sports and Exercise, 34 (6). pp. 960-965. ISSN 0195-9131 (print) 1530-0315 (online)

Abstract

Purpose: Brachial artery flow-mediated dilation (BAFMD) is a noninvasive technique, which has been suggested as a potential means of identifying patients with early atherosclerosis and therefore has enormous clinical appeal. Despite this, the stability and reproducibility of this technique are not yet clear. Therefore, the purpose of this study was to establish the stability and reproducibility of BAFMD after 5 min of forearm occlusion and to produce power calculations to aid in clinical trial design. Methods: Twenty-six healthy volunteers underwent high-resolution ultrasonographic brachial artery assessments before, during, and after 5 min of forearm occlusion. The study design involved three scans on 2 d, performed by two ultrasonographers and analyzed by two readers. All subjects were tested between 7 and 11 a.m. after refraining from food and exercise. The nondominant arms were scanned, in longitudinal view, approximately 4 cm proximal to the olecranon process, in the anterior/medial plane. Blood draws were performed on each visit. The SAS MIXED restricted maximum likelihood (REML) procedure for an unbalanced design was used to calculate variance components and provide power calculations. Results: Average baseline artery diameter for all studies was 3.48 ± 0.53 mm. This increased to 3.71 ± 0.57 mm (6.58 ± 4.15%) at peak dilation. Intraclass correlation coefficients (ICCC) for days, testers, and readers were 0.92, 0.94, and 0.90, respectively. To detect a difference in vasoreactivity of 60% (two-tailed), e.g., 5% vasodilation versus 8% vasodilation, at 90% power, 23 and 10 subjects would be required for cross-sectional and pre-post designs, respectively. Conclusions: These data indicate adequate stability and reproducibility of the BAFMD technique under controlled conditions. Additionally, BAFMD appears useful to differentiate between groups, although its prognostic value for the examination of individuals is unclear.

Dimensions Badge

Altmetric Badge

Item type Article
URI https://vuir.vu.edu.au/id/eprint/25769
DOI 10.1097/00005768-200206000-00009
Official URL http://dx.doi.org/10.1097/00005768-200206000-00009
Subjects Historical > FOR Classification > 1103 Clinical Sciences
Current > Division/Research > College of Sports and Exercise Science
Keywords technique, vascular, atherosclerosis, vasoreactivity
Citations in Scopus 60 - View on Scopus
Download/View statistics View download statistics for this item

Search Google Scholar

Repository staff login