The Validity and Reliability of GPS Units for Measuring Distance in Team Sport Specific Running Patterns

Full text for this resource is not available from the Research Repository.

Jennings, Denise, Cormack, Stuart, Coutts, Aaron, Boyd, Luke and Aughey, Robert ORCID: 0000-0002-0285-8516 (2010) The Validity and Reliability of GPS Units for Measuring Distance in Team Sport Specific Running Patterns. International Journal of Sports Physiology and Performance, 5 (3). pp. 328-341. ISSN 1555-0265

Abstract

Purpose: To assess the validity and reliability of distance data measured by global positioning system (GPS) units sampling at 1 and 5 Hz during movement patterns common to team sports. Methods: Twenty elite Australian Football players each wearing two GPS devices (MinimaxX, Catapult, Australia) completed straight line movements (10, 20, 40 m) at various speeds (walk, jog, stride, sprint), changes of direction (COD) courses of two different frequencies (gradual and tight), and a team sport running simulation circuit. Position and speed data were collected by the GPS devices at 1 and 5 Hz. Distance validity was assessed using the standard error of the estimate (±90% confidence intervals [CI]). Reliability was estimated using typical error (TE) ± 90% CI (expressed as coefficient of variation [CV]). Results: Measurement accuracy decreased as speed of locomotion increased in both straight line and the COD courses. Difference between criterion and GPS measured distance ranged from 9.0% to 32.4%. A higher sampling rate improved validity regardless of distance and locomotion in the straight line, COD and simulated running circuit trials. The reliability improved as distance traveled increased but decreased as speed increased. Total distance over the simulated running circuit exhibited the lowest variation (CV 3.6%) while sprinting over 10 m demonstrated the highest (CV 77.2% at 1 Hz). Conclusion: Current GPS systems maybe limited for assessment of short, high speed straight line running and efforts involving change of direction. An increased sample rate improves validity and reliability of GPS devices

Dimensions Badge

Altmetric Badge

Item type Article
URI https://vuir.vu.edu.au/id/eprint/7242
DOI 10.1123/ijspp.5.3.328
Official URL https://journals.humankinetics.com/doi/abs/10.1123...
Subjects Historical > Faculty/School/Research Centre/Department > Institute of Sport, Exercise and Active Living (ISEAL)
Historical > FOR Classification > 1106 Human Movement and Sports Science
Historical > SEO Classification > 970111 Expanding Knowledge in the Medical and Health Sciences
Keywords ResPubID20367, time-motion analysis, accuracy, precision, acceleration
Citations in Scopus 310 - View on Scopus
Download/View statistics View download statistics for this item

Search Google Scholar

Repository staff login