Cerebral oxygenation decreases but does not impair performance during self-paced, strenuous exercise

Full text for this resource is not available from the Research Repository.

Billaut, Francois, Davis, J, Smith, KJ, Marino, F and Noakes, T (2010) Cerebral oxygenation decreases but does not impair performance during self-paced, strenuous exercise. Acta Physiologica, 198 (4). pp. 477-486. ISSN 1748-1708

Abstract

Aim:  The reduction in cerebral oxygenation (Cox) is associated with the cessation of exercise during constant work rate and incremental tests to exhaustion. Yet in exercises of this nature, ecological validity is limited due to work rate being either fully or partly dictated by the protocol, and it is unknown whether cerebral deoxygenation also occurs during self-paced exercise. Here, we investigated the cerebral haemodynamics during a 5-km running time trial in trained runners. Methods:  Rating of perceived exertion (RPE) and surface electromyogram (EMG) of lower limb muscles were recorded every 0.5 km. Changes in Cox (prefrontal lobe) were monitored via near-infrared spectroscopy through concentration changes in oxy- and deoxyhaemoglobin (Δ[O2Hb], Δ[HHb]). Changes in total Hb were calculated (Δ[THb] = Δ[O2Hb] + Δ[HHb]) and used as an index of change in regional blood volume. Results:  During the trial, RPE increased from 6.6 ± 0.6 to 19.1 ± 0.7 indicating maximal exertion. Cox rose from baseline to 2.5 km (↑Δ[O2Hb], ↑Δ[HHb], ↑Δ[THb]), remained constant between 2.5 and 4.5 km, and fell from 4.5 to 5 km (↓Δ[O2Hb], ↑Δ[HHb], ↔Δ[THb]). Interestingly, the drop in Cox at the end of the trial coincided with a final end spurt in treadmill speed and concomitant increase in skeletal muscle recruitment (as revealed by higher lower limb EMG). Conclusion:  Results confirm the large tolerance for change in Cox during exercise at sea level, yet further indicate that, in conditions of self-selected work rate, cerebral deoxygenation remains within a range that does not hinder strenuous exercise performance.

Dimensions Badge

Altmetric Badge

Item type Article
URI https://vuir.vu.edu.au/id/eprint/7930
DOI 10.1111/j.1748-1716.2009.02058.x
Official URL http://dx.doi.org/10.1111/j.1748-1716.2009.02058.x
Subjects Historical > Faculty/School/Research Centre/Department > Institute of Sport, Exercise and Active Living (ISEAL)
Historical > FOR Classification > 1106 Human Movement and Sports Science
Keywords ResPubID21959, brain oxygenation, cerebral blood flow, near infrared spectroscopy, pacing
Citations in Scopus 59 - View on Scopus
Download/View statistics View download statistics for this item

Search Google Scholar

Repository staff login